Tonometer Goldmann - X Type Best for Slit Lamp Zeiss Style

Tonometer is an important instrument to measure the intraocular pressure. Following the principle of Goldmann applanation tonometer, the applanation tonometer press flat a certain area (3.06mm diameter) of patient’s cornea with different pressure through pressure-measuring probe inlaid with a prism. Under slit lamp microscope, and with the help of illumination of fluorescence and blue rays, two green semi-circles whose inner parts connect each other can be seen. Thus, numerical value of intraocuolar pressure (IOP) can be got from the reading turn drum. As the cornea area pressed flat by the tonometer is very small, change of IOP caused by outer force is also very small. The eye pressure we get is nearer to the true value of IOP as compared with Schiötz tonometer, with the mean error no more than ±0.266Kpa. It is one of the commonly-used tonometer.

Main Specifications

Measuring range: 0~10.6Kpa

Movement of light circle: 1.53´2=3.06mm

Diameter of probe: 7mm

Moving range of probe: 3mm

With slit lamps: serials of Crane and others with suspension arm interface

Wight: 950g Size: 210´150´85 mm

Tonometer Goldmann-X Type INS-11013-3

SKU: INS-11013-3
Regular price $643.00
Unit price
per 
Fast Shipping
Secure payment
Availability
 
Shipping calculated at checkout.

Click here to download Manual

 

Tonometer Goldmann - X Type Best for Slit Lamp Zeiss Style

Tonometer is an important instrument to measure the intraocular pressure. Following the principle of Goldmann applanation tonometer, the applanation tonometer press flat a certain area (3.06mm diameter) of patient’s cornea with different pressure through pressure-measuring probe inlaid with a prism. Under slit lamp microscope, and with the help of illumination of fluorescence and blue rays, two green semi-circles whose inner parts connect each other can be seen. Thus, numerical value of intraocuolar pressure (IOP) can be got from the reading turn drum. As the cornea area pressed flat by the tonometer is very small, change of IOP caused by outer force is also very small. The eye pressure we get is nearer to the true value of IOP as compared with Schiötz tonometer, with the mean error no more than ±0.266Kpa. It is one of the commonly-used tonometer.

Main Specifications

Measuring range: 0~10.6Kpa

Movement of light circle: 1.53´2=3.06mm

Diameter of probe: 7mm

Moving range of probe: 3mm

With slit lamps: serials of Crane and others with suspension arm interface

Wight: 950g Size: 210´150´85 mm